Home Inspection Services
Henry Sobczak
NJ Licensed Home Inspector
Services available; - Home/Building/Structural Inspections - - Wood Destroying Insect Inspection and Certification - - Radon Testing - - Lead Paint Testing - - Septic System Inspections - - Oil Tank Testing - - Commercial Building Inspections (size limited)- - Multi-Family Dwelling Inspections - 1 year Home Warranty is available for as little as $2.45 a day through East Coast Warranty My reporting system and report is custom "built" to your property inspection I don't like to rush the home inspection, remember, you only get "one shot" to find potential problems before you buy the house Anything of good quality takes time. Make it count the first time around I want to make sure that you, the buyer, get the very best report I can provide American Society of Home Inspectors (ASHI®) Standards of Practice Standards of Practice The ASHI® Standards of Practice guide home inspectors in the performance of their inspections. Subject to regular review, the Standards of Practice reflect information gained through surveys of conditions in the field and of the consumers’ interests and concerns. Vigilance has elevated ASHI’s® Standards of Practice so that today they are the most widely-accepted home inspection guidelines in use and are recognized by many government and professional groups as the definitive standard for professional performance Code of Ethics ASHI’s® Code of Ethics stresses the home inspector’s responsibility to report the results of the inspection in a strictly fair, impartial, and professional manner, avoiding conflicts of interest. ASHI® Membership Selecting the right home inspector can be as important as finding the right home. ASHI® Members have performed no fewer than 250 fee-paid inspections in accordance with the ASHI® Standards of Practice. They have passed written examinations testing their knowledge of residential construction, defect recognition, inspection techniques, and report-writing, as well as ASHI’s® Standards of Practice and Code of Ethics. Membership in the American Society of Home Inspectors is well-earned and maintained only through meeting requirements for continuing education. 1. INTRODUCTION The American Society of Home Inspectors®, Inc. (ASHI®) is a not-for-profit professional society established in 1976. Membership in ASHI® is voluntary and its members are private home inspectors. ASHI’s® objectives include promotion of excellence within the profession and continual improvement of its members’ inspection services to the public. 2.1 The purpose of the Standards of Practice is to establish a minimum and uniform standard for home inspectors who subscribe to these Standards of Practice. Home inspections performed to these Standards of Practice are intended to provide the client with objective information regarding the condition of the systems and components of the home as inspected at the time of the home inspection. Redundancy in the description of the requirements, limitations, and exclusions regarding the scope of the home inspection is provided for emphasis only. 2. PURPOSE AND SCOPE 2.2 Inspectors shall: A. adhere to the Code of Ethics of the American Society of Home Inspectors. B. inspect readily accessible, visually observable, installed systems and components as listed in these Standards of Practice. C. report: 1. those systems and components inspected that, in the professional judgment of the inspector, are not functioning properly, significantly deficient, unsafe, or are near the end of their service lives. 2. recommendations to correct, or monitor for future correction, the deficiencies reported in 2.2.C.1, or items needing further evaluation. (Per Exclusion 13.2.A.) 3. reasoning or explanation as to the nature of the deficiencies reported in 2.2.C.1, that are not self-evident. 4. systems and components designated for inspection in these Standards of Practice that were present at the time of the home inspection but were not inspected and the reason(s) they were not inspected. 5. inspectors are NOT required to determine methods, materials, or costs of corrections. 2.3 These Standards of Practice are not intended to limit inspectors from: A. including other inspection services or systems and components in addition to those required in Section 2.2.B. B. designing or specifying repairs, provided the inspector is appropriately qualified and willing to do so. C. excluding systems and components from the inspection if requested by the client. 3. STRUCTURAL COMPONENTS 3.1 The inspector shall: A. inspect: 1. structural components including the foundation and framing. 2. by probing a representative number of structural components where deterioration is suspected or where clear indications of possible deterioration exist. Probing is NOT required when probing would damage any finished surface or where no deterioration is visible or presumed to exist. B. describe: 1. the methods used to inspect under-floor crawl spaces and attics. 2. the foundation. 3. the floor structure. 4. the wall structure. 5. the ceiling structure. 6. the roof structure. 3.2 The inspector is NOT required to: A. provide any engineering or architectural services or analysis. B. offer an opinion as to the adequacy of any structural system or component. 4. EXTERIOR 4.1 The inspector shall: A. inspect: 1. siding, flashing and trim. 2. all exterior doors. 3. attached or adjacent decks, balconies, stoops, steps, porches, and their associated railings. 4. eaves, soffits, and fascias where accessible from the ground level. 5. vegetation, grading, surface drainage, and retaining walls that are likely to adversely affect the building. 6. adjacent or entryway walkways, patios, and driveways. 4. EXTERIOR 4.1 The inspector shall: B. describe: 1. siding. 4.2 The inspector is NOT required to inspect: A. screening, shutters, awnings, and similar seasonal accessories. B. fences. C. geological and/or soil conditions. D. recreational facilities. E. outbuildings other than garages and carports. F. seawalls, break-walls, and docks. G. erosion control and earth stabilization measures. 5. ROOFING 5.1 The inspector shall: A. inspect: 1. roofing materials. 2. roof drainage systems. 3. flashing. 4. skylights, chimneys, and roof penetrations. B. describe: 1. roofing materials. 2. methods used to inspect the roofing. 5.2 The inspector is NOT required to inspect: A. antennae. B. interiors of flues or chimneys that are not readily accessible. C. other installed accessories. 6. PLUMBING 6.1 The inspector shall: A. inspect: 1. interior water supply and distribution systems including all fixtures and faucets. 2. drain, waste, and vent systems including all fixtures. 3. water heating equipment and hot water supply system. 4. vent systems, flues, and chimneys. 5. fuel storage and fuel distribution systems. 6. drainage sumps, sump pumps, and related piping. B. describe: 1. water supply, drain, waste, and vent piping materials. 2. water heating equipment including energy source(s). 3. location of main water and fuel shut-off valves. 6.2 The inspector is NOT required to: A. inspect: 1. clothes washing machine connections. 2. interiors of flues or chimneys that are not readily accessible. 3. wells, well pumps, or water storage related equipment. 4. water conditioning systems. 5. solar water heating systems. 6. fire and lawn sprinkler systems. 7. private waste disposal systems. B. determine: 1. whether water supply and waste disposal systems are public or private. 2. water supply quantity or quality. 3. operate automatic safety controls or manual stop valves. 7. ELECTRICAL 7.1 The inspector shall: A. inspect: 1. service drop. 2. service entrance conductors, cables, and raceways. 3. service equipment and main disconnects. 4. service grounding. 5. interior components of service panels and sub panels. 6. conductors. 7. over current protection devices. 8. a representative number of installed lighting fixtures, switches, and receptacles. 9. ground fault circuit interrupters. B. describe: 1. amperage and voltage rating of the service. 2. location of main disconnect(s) and sub panels. 3. presence of solid conductor aluminum branch circuit wiring. 4. presence or absence of smoke detectors. 5. wiring methods. 7.2 The inspector is NOT required to A. inspect: 1. remote control devices 2. alarm systems and components. 3. low voltage wiring systems and components. 4. ancillary wiring systems and components. not a part of the primary electrical power distribution system. B. measure amperage, voltage, or impedance. 8. HEATING 8.1 The inspector shall: A. open readily openable access panels. B. inspect: 1. installed heating equipment. 2. vent systems, flues, and chimneys C. describe: 1. energy source(s). 2. heating systems. 8.2 The inspector is NOT required to: A. inspect: 1. interiors of flues or chimneys that are not readily accessible. 2. heat exchangers. 3. humidifiers or dehumidifiers. 4. electronic air filters. 5. solar space heating systems. B. determine heat supply adequacy or distribution balance. 9. AIR CONDITIONING 9.1 The inspector shall: A. open readily openable access panels. B. inspect: 1. central and through-wall equipment. 2. distribution systems. C. describe: 1. energy source(s). 2. cooling systems. 9.2 The inspector is NOT required to: B. inspect: A. inspect electronic air filters. B. determine cooling supply adequacy or distribution balance. C. inspect window air conditioning units 10. INTERIORS 10.1 The inspector shall inspect: B. inspect: A. walls, ceilings, and floors. B. steps, stairways, and railings. C. countertops and a representative number of installed cabinets. D. a representative number of doors and windows. E. garage doors and garage door operators. 10.2 The inspector is NOT required to inspect: B. inspect: A. paint, wallpaper, and other finish treatments. B. carpeting. C. window treatments. D. central vacuum systems. E. household appliances. F. recreational facilities. 11. INSULATION & VENTILATION 11.1 The inspector shall: A. inspect: 1. insulation and vapor retarders in unfinished spaces. 2. ventilation of attics and foundation areas. 3. mechanical ventilation systems. B. describe: 1. insulation and vapor retarders in unfinished spaces. 2. absence of insulation in unfinished spaces at conditioned surfaces 11.2 The inspector is NOT required to disturb insulation. See 13.2.A.11 and 13.2.A.12. 12. FIREPLACES AND SOLID FUEL BURNING APPLIANCES 12.1 The inspector shall: A. inspect: 1. system components. 2. chimney and vents. B. describe: 1. fireplaces and solid fuel burning appliances. 2. chimneys. 12.2 The inspector is NOT required to: A. inspect: 1. interiors of flues or chimneys. 2. firescreens and doors. 3. seals and gaskets. 4. automatic fuel feed devices. 5. mantles and fireplace surrounds. 6. combustion make-up air devices. 7. heat distribution assists (gravity fed and fan assisted). B. ignite or extinguish fires. C. determine draft characteristics. D. move fireplace inserts and stoves or firebox contents 13. GENERAL LIMITATIONS AND EXCLUSIONS 13.1 General limitations: A. The inspector is NOT required to perform any action or make any determination not specifically stated in these Standards of Practice. B. Inspections performed in accordance with these Standards of Practice: 2. are not required to identify concealed. conditions, latent defects, or consequential damage(s). C. These Standards of Practice are applicable to buildings with four or fewer dwelling units and their garages or carports. 13.2 GENERAL EXCLUSIONS A. Inspectors are NOT required to determine: 1. conditions of systems or components that are not readily accessible. 2. remaining life expectancy of any system or component. 3. strength, adequacy, effectiveness, or efficiency of any system or component. 4. the causes of any condition or deficiency. 5. methods, materials, or costs of corrections. 6. future conditions including but not limited to failure of systems and components. 7. the suitability of the property for any specialized use. 8. compliance with regulatory requirements (codes, regulations, laws, ordinances, etc.). 9. market value of the property or its marketability. 10. the advisability of purchase of the property. 11. the presence of potentially hazardous plants or animals including, but not limited to, wood destroying organisms or diseases harmful to humans including molds or mold-like substances. 12. the presence of any environmental hazards including, but not limited to, toxins, carcinogens, noise, and contaminants in soil, water, and air. 13. the effectiveness of any system installed or method utilized to control or remove suspected hazardous substances. 14. operating costs of systems or components. 15. acoustical properties of any system or component. 16. soil conditions relating to geotechnical or hydrologic specialties. B. Inspectors are NOT required to offer: 1. or perform any act or service contrary to law. 2. or perform engineering services. 3. or perform any trade or any professional. service other than home inspection. 4. warranties or guarantees of any kind. C. Inspectors are NOT required to operate: 1. any system or component that is shut down or otherwise inoperable. 2. any system or component that does not respond to normal operating controls. 3. shut-off valves or manual stop valves. D. Inspectors are NOT required to enter: 1. any area that will, in the opinion of the inspector, likely be dangerous to the inspector or other persons or damage the property or its systems or components. 2. under-floor crawl spaces or attics that are not readily accessible. E. Inspectors are NOT required to inspect: 1. underground items including but not limited to underground storage tanks or other underground indications of their presence, whether abandoned or active. 2. items that are not installed. 3. installed decorative items. 4. items in areas that are not entered in accordance with 13.2.D. 5. detached structures other than garages and carports. 6. common elements or common areas in multi-unit housing, such as condominium properties or cooperative housing. F. Inspectors are NOT required to: 1. perform any procedure or operation that will, in the opinion of the inspector, likely be dangerous to the inspector or other persons or damage the property or its systems or components. 2. describe or report on any system or component that is not included in these Standards and was not inspected. 3. move personal property, furniture, equipment, plants, soil, snow, ice, or debris. 4. dismantle any system or component, except as explicitly required by these Standards of Practice. DEFINITIONS; Alarm Systems; Warning devices installed or freestanding including but not limited to smoke detectors, carbon monoxide detectors, flue gas, and other spillage detectors, and security equipment Automatic Safety Controls; Devices designed and installed to protect systems and components from unsafe conditions Component; A part of a system Decorative; Ornamental; not required for the proper operation of the essential systems and components of a home Describe; To identify (in writing) a system or component by its type or other distinguishing characteristics Dismantle; To take apart or remove any component, device, or piece of equipment that would not be taken apart or removed by a homeowner in the course of normal maintenance Engineering; The application of scientific knowledge for the design, control, or use of building structures, equipment, or apparatus Further Evaluation; Examination and analysis by a qualified professional, tradesman, or service technician beyond that provided by the home inspection Home Inspection; The process by which an inspector visually examines the readily accessible systems and components of a home and which describes those systems and components in accordance with these Standards of Practice Household Appliances; Kitchen, laundry, and similar appliances, whether installed or free-standing Inspect; To examine any system or component of a building in accordance with these Standards of Practice, using normal operating controls and opening readily openable access panels Inspector; A person hired to examine any system or component of a building in accordance with these Standards of Practice Installed; Attached such that removal requires tools Normal Operating Controls; Devices such as thermostats, switches, or valves intended to be operated by the homeowner Readily Accessible; Available for visual inspection without requiring moving of personal property, dismantling, destructive measures, or any action that will likely involve risk to persons or property Readily Openable Access Panel; A panel provided for homeowner inspection and maintenance that is readily accessible, within normal reach, can be removed by one person, and is not sealed in place Recreational Facilities; Spas, saunas, steam baths, swimming pools, exercise, entertainment, athletic, playground or other similar equipment, and associated accessories Report; Communicate in writing Representative Number; One component per room for multiple similar interior components such as windows, and electric receptacles; one component on each side of the building for multiple similar exterior components Roof Drainage Systems; Components used to carry water off a roof and away from a building Shut Down; A state in which a system or component cannot be operated by normal operating controls Siding; Exterior wall covering and cladding; such as: aluminum, asphalt, brick, cement/asbestos, EIFS, stone, stucco, veneer, vinyl, wood, etc. Solid Fuel Burning Appliances; A hearth and fire chamber or similar prepared place in which a fire may be built and that is built in conjunction with a chimney; or a listed assembly of a fire chamber, its chimney, and related factory- made parts designed for unit assembly without requiring field construction Structural Component; A component that supports non-variable forces or weights (dead loads) and variable forces or weights (live loads) System; A combination of interacting or interdependent components, assembled to carry out one or more functions. Technically Exhaustive; An investigation that involves dismantling, the extensive use of advanced techniques, measurements, instruments, testing, calculations, or other means Under-floor Crawl Space; The area within the confines of the foundation and between the ground and the underside of the floor Unsafe; A condition in a readily accessible, installed system or component that is judged to be a significant risk of bodily injury during normal, day-to-day use; the risk may be due to damage, deterioration, improper installation, or a change in accepted Wiring Methods; Identification of electrical conductors or wires by their general type, such as non- metallic sheathed cable, armored cable,or knob and tube, etc.
Services available;
- Home/Building/Structural Inspections -
- Wood Destroying Insect Inspection and Certification -
- Radon Testing -
- Lead Paint Testing -
- Septic System Inspections -
- Oil Tank Testing -
- Commercial Building Inspections (size limited)-
- Multi-Family Dwelling Inspections -
1 year Home Warranty is available for as little as $2.45 a day through East Coast Warranty
My reporting system and report is custom "built" to your property inspection I don't like to rush the home inspection, remember, you only get "one shot" to find potential problems before you buy the house
Anything of good quality takes time. Make it count the first time around
I want to make sure that you, the buyer, get the very best report I can provide
American Society of Home Inspectors (ASHI®)
Standards of Practice
The ASHI® Standards of Practice guide home inspectors in the performance of their inspections. Subject to regular
review, the Standards of Practice reflect information gained through surveys of conditions in the field and of the
consumers’ interests and concerns. Vigilance has elevated ASHI’s® Standards of Practice so that today they are the
most widely-accepted home inspection guidelines in use and are recognized by many government and professional groups as the definitive standard for professional performance
ASHI’s® Code of Ethics stresses the home inspector’s responsibility to report the results of the inspection in a strictly fair, impartial, and professional manner, avoiding conflicts of interest.
Selecting the right home inspector can be as important as finding the right home. ASHI® Members have performed no fewer than 250 fee-paid inspections in accordance with the ASHI® Standards of Practice. They have passed written examinations testing their knowledge of residential construction, defect recognition, inspection techniques, and report-writing, as well as ASHI’s® Standards of Practice and Code of Ethics. Membership in the American Society of Home Inspectors is well-earned and maintained only through meeting requirements for continuing education.
The American Society of Home Inspectors®, Inc. (ASHI®) is a not-for-profit professional society established in 1976. Membership in ASHI® is voluntary and its members are private home inspectors. ASHI’s® objectives include promotion of excellence within the profession and continual improvement of its members’ inspection services to the public.
2.1 The purpose of the Standards of Practice is to establish a minimum and uniform standard for home inspectors who subscribe to these Standards of Practice. Home inspections performed to these Standards of Practice are intended to provide the client with objective information regarding the condition of the systems and components of the home as inspected at the time of the home inspection. Redundancy in the description of the requirements, limitations, and exclusions regarding the scope of the home inspection is provided for emphasis only.
2.2 Inspectors shall:
A. adhere to the Code of Ethics of the American Society of Home Inspectors.
B. inspect readily accessible, visually observable, installed systems and components as listed in these Standards of Practice.
C. report:
1. those systems and components inspected that, in the professional judgment of the inspector, are not functioning properly, significantly deficient, unsafe, or are near the end of their service lives.
2. recommendations to correct, or monitor for future correction, the deficiencies reported in 2.2.C.1, or items needing further evaluation. (Per Exclusion 13.2.A.)
3. reasoning or explanation as to the nature of the deficiencies reported in 2.2.C.1, that are not self-evident.
4. systems and components designated for inspection in these Standards of Practice that were present at the time of the home inspection but were not inspected and the reason(s) they were not inspected.
5. inspectors are NOT required to determine methods, materials, or costs of corrections.
2.3 These Standards of Practice are not intended to limit inspectors from:
A. including other inspection services or systems and components in addition to those required in Section 2.2.B.
B. designing or specifying repairs, provided the inspector is appropriately qualified and willing to do so.
C. excluding systems and components from the inspection if requested by the client.
3.1 The inspector shall:
A. inspect:
1. structural components including the foundation and framing.
2. by probing a representative number of structural components where deterioration is suspected or where clear
indications of possible deterioration exist. Probing is NOT required when probing would damage any finished
surface or where no deterioration is visible or presumed to exist.
B. describe:
1. the methods used to inspect under-floor crawl spaces and attics.
2. the foundation.
3. the floor structure.
4. the wall structure.
5. the ceiling structure.
6. the roof structure.
3.2 The inspector is NOT required to:
A. provide any engineering or architectural services or analysis.
B. offer an opinion as to the adequacy of any structural system or component.
4.1 The inspector shall:
1. siding, flashing and trim.
2. all exterior doors.
3. attached or adjacent decks, balconies, stoops, steps, porches, and their associated railings.
4. eaves, soffits, and fascias where accessible from the ground level.
5. vegetation, grading, surface drainage, and retaining walls that are likely to adversely affect the building.
6. adjacent or entryway walkways, patios, and driveways.
1. siding.
4.2 The inspector is NOT required to inspect:
A. screening, shutters, awnings, and similar seasonal accessories.
B. fences.
C. geological and/or soil conditions.
D. recreational facilities.
E. outbuildings other than garages and carports.
F. seawalls, break-walls, and docks.
G. erosion control and earth stabilization measures.
5.1 The inspector shall:
1. roofing materials.
2. roof drainage systems.
3. flashing.
4. skylights, chimneys, and roof penetrations.
2. methods used to inspect the roofing.
5.2 The inspector is NOT required to inspect:
A. antennae.
B. interiors of flues or chimneys that are not readily accessible.
C. other installed accessories.
6.1 The inspector shall:
1. interior water supply and distribution systems including all fixtures and faucets.
2. drain, waste, and vent systems including all fixtures.
3. water heating equipment and hot water supply system.
4. vent systems, flues, and chimneys.
5. fuel storage and fuel distribution systems.
6. drainage sumps, sump pumps, and related piping.
1. water supply, drain, waste, and vent piping materials.
2. water heating equipment including energy source(s).
3. location of main water and fuel shut-off valves.
6.2 The inspector is NOT required to:
1. clothes washing machine connections.
2. interiors of flues or chimneys that are not readily accessible.
3. wells, well pumps, or water storage related equipment.
4. water conditioning systems.
5. solar water heating systems.
6. fire and lawn sprinkler systems.
7. private waste disposal systems.
B. determine:
1. whether water supply and waste disposal systems are public or private.
2. water supply quantity or quality.
3. operate automatic safety controls or manual stop valves.
7.1 The inspector shall:
1. service drop.
2. service entrance conductors, cables, and raceways.
3. service equipment and main disconnects.
4. service grounding.
5. interior components of service panels and sub panels.
6. conductors.
7. over current protection devices.
8. a representative number of installed lighting fixtures, switches, and receptacles.
9. ground fault circuit interrupters.
1. amperage and voltage rating of the service.
2. location of main disconnect(s) and sub panels.
3. presence of solid conductor aluminum branch circuit wiring.
4. presence or absence of smoke detectors.
5. wiring methods.
7.2 The inspector is NOT required to
1. remote control devices
2. alarm systems and components.
3. low voltage wiring systems and components.
4. ancillary wiring systems and components. not a part of the primary electrical power distribution system.
B. measure amperage, voltage, or impedance.
8.1 The inspector shall:
A. open readily openable access panels.
B. inspect:
1. installed heating equipment.
2. vent systems, flues, and chimneys
C. describe:
1. energy source(s).
2. heating systems.
1. interiors of flues or chimneys that are not readily accessible.
2. heat exchangers.
3. humidifiers or dehumidifiers.
4. electronic air filters.
5. solar space heating systems.
B. determine heat supply adequacy or distribution balance.
9.1 The inspector shall:
1. central and through-wall equipment.
2. distribution systems.
2. cooling systems.
9.2 The inspector is NOT required to:
A. inspect electronic air filters.
B. determine cooling supply adequacy or distribution balance.
C. inspect window air conditioning units
10.1 The inspector shall inspect:
A. walls, ceilings, and floors.
B. steps, stairways, and railings.
C. countertops and a representative number of installed cabinets.
D. a representative number of doors and windows.
E. garage doors and garage door operators.
10.2 The inspector is NOT required to inspect:
A. paint, wallpaper, and other finish treatments.
B. carpeting.
C. window treatments.
D. central vacuum systems.
E. household appliances.
F. recreational facilities.
11.1 The inspector shall:
1. insulation and vapor retarders in unfinished spaces.
2. ventilation of attics and foundation areas.
3. mechanical ventilation systems.
2. absence of insulation in unfinished spaces at conditioned surfaces
11.2 The inspector is NOT required to disturb insulation.
See 13.2.A.11 and 13.2.A.12.
12.1 The inspector shall:
1. system components.
2. chimney and vents.
1. fireplaces and solid fuel burning appliances.
2. chimneys.
12.2 The inspector is NOT required to:
1. interiors of flues or chimneys.
2. firescreens and doors.
3. seals and gaskets.
4. automatic fuel feed devices.
5. mantles and fireplace surrounds.
6. combustion make-up air devices.
7. heat distribution assists (gravity fed and fan assisted).
B. ignite or extinguish fires.
C. determine draft characteristics.
D. move fireplace inserts and stoves or firebox contents
13.1 General limitations:
A. The inspector is NOT required to perform any action or make any determination not specifically stated in these Standards of Practice.
B. Inspections performed in accordance with these Standards of Practice:
2. are not required to identify concealed. conditions, latent defects, or consequential damage(s).
C. These Standards of Practice are applicable to buildings with four or fewer dwelling units and their garages or carports.
A. Inspectors are NOT required to determine:
1. conditions of systems or components that are not readily accessible.
2. remaining life expectancy of any system or component.
3. strength, adequacy, effectiveness, or efficiency of any system or component.
4. the causes of any condition or deficiency.
5. methods, materials, or costs of corrections.
6. future conditions including but not limited to failure of systems and components.
7. the suitability of the property for any specialized use.
8. compliance with regulatory requirements (codes, regulations, laws, ordinances, etc.).
9. market value of the property or its marketability.
10. the advisability of purchase of the property.
11. the presence of potentially hazardous plants or animals including, but not limited to, wood destroying organisms or diseases harmful to humans including molds or mold-like substances.
12. the presence of any environmental hazards including, but not limited to, toxins, carcinogens, noise, and contaminants in soil, water, and air.
13. the effectiveness of any system installed or method utilized to control or remove suspected hazardous substances.
14. operating costs of systems or components.
15. acoustical properties of any system or component.
16. soil conditions relating to geotechnical or hydrologic specialties.
B. Inspectors are NOT required to offer:
1. or perform any act or service contrary to law.
2. or perform engineering services.
3. or perform any trade or any professional. service other than home inspection.
4. warranties or guarantees of any kind.
C. Inspectors are NOT required to operate:
1. any system or component that is shut down or otherwise inoperable.
2. any system or component that does not respond to normal operating controls.
3. shut-off valves or manual stop valves.
D. Inspectors are NOT required to enter:
1. any area that will, in the opinion of the inspector, likely be dangerous to the inspector or other persons or damage the property or its systems or components.
2. under-floor crawl spaces or attics that are not readily accessible.
E. Inspectors are NOT required to inspect:
1. underground items including but not limited to underground storage tanks or other underground indications of their presence, whether abandoned or active.
2. items that are not installed.
3. installed decorative items.
4. items in areas that are not entered in accordance with 13.2.D.
5. detached structures other than garages and carports.
6. common elements or common areas in multi-unit housing, such as condominium properties or cooperative housing.
F. Inspectors are NOT required to:
1. perform any procedure or operation that will, in the opinion of the inspector, likely be dangerous to the inspector or other persons or damage the property or its systems or components.
2. describe or report on any system or component that is not included in these Standards and was not inspected.
3. move personal property, furniture, equipment, plants, soil, snow, ice, or debris.
4. dismantle any system or component, except as explicitly required by these Standards of Practice.
DEFINITIONS;
Alarm Systems; Warning devices installed or freestanding including but not limited to smoke detectors, carbon
monoxide detectors, flue gas, and other spillage detectors, and security equipment
Automatic Safety Controls; Devices designed and installed to protect systems and components from unsafe
conditions
Component; A part of a system
Decorative; Ornamental; not required for the proper operation of the essential systems and components of a home
Describe; To identify (in writing) a system or component by its type or other distinguishing characteristics
Dismantle; To take apart or remove any component, device, or piece of equipment that would not be taken apart
or removed by a homeowner in the course of normal maintenance
Engineering; The application of scientific knowledge for the design, control, or use of building structures,
equipment, or apparatus
Further Evaluation; Examination and analysis by a qualified professional, tradesman, or service technician beyond
that provided by the home inspection
Home Inspection; The process by which an inspector visually examines the readily accessible systems and
components of a home and which describes those systems and components in accordance with these Standards
of Practice
Household Appliances; Kitchen, laundry, and similar appliances, whether installed or free-standing
Inspect; To examine any system or component of a building in accordance with these Standards of Practice, using
normal operating controls and opening readily openable access panels
Inspector; A person hired to examine any system or component of a building in accordance with these Standards of Practice
Installed; Attached such that removal requires tools
Normal Operating Controls; Devices such as thermostats, switches, or valves intended to be operated by the
homeowner
Readily Accessible; Available for visual inspection without requiring moving of personal property, dismantling,
destructive measures, or any action that will likely involve risk to persons or property
Readily Openable Access Panel; A panel provided for homeowner inspection and maintenance that is readily
accessible, within normal reach, can be removed by one person, and is not sealed in place
Recreational Facilities; Spas, saunas, steam baths, swimming pools, exercise, entertainment, athletic, playground
or other similar equipment, and associated accessories
Report; Communicate in writing
Representative Number; One component per room for multiple similar interior components such as windows, and
electric receptacles; one component on each side of the building for multiple similar exterior components
Roof Drainage Systems; Components used to carry water off a roof and away from a building
Shut Down; A state in which a system or component cannot be operated by normal operating controls
Siding; Exterior wall covering and cladding; such as: aluminum, asphalt, brick, cement/asbestos, EIFS, stone,
stucco, veneer, vinyl, wood, etc.
Solid Fuel Burning Appliances; A hearth and fire chamber or similar prepared place in which a fire may be built and
that is built in conjunction with a chimney; or a listed assembly of a fire chamber, its chimney, and related factory-
made parts designed for unit assembly without requiring field construction
Structural Component; A component that supports non-variable forces or weights (dead loads) and variable forces
or weights (live loads)
System; A combination of interacting or interdependent components, assembled to carry out one or more functions.
Technically Exhaustive; An investigation that involves dismantling, the extensive use of advanced techniques,
measurements, instruments, testing, calculations, or other means
Under-floor Crawl Space; The area within the confines of the foundation and between the ground and the
underside of the floor
Unsafe; A condition in a readily accessible, installed system or component that is judged to be a significant risk of
bodily injury during normal, day-to-day use; the risk may be due to damage, deterioration, improper installation, or
a change in accepted
Wiring Methods; Identification of electrical conductors or wires by their general type, such as non-
metallic sheathed cable, armored cable,or knob and tube, etc.